JLS300 Series Servo Drive
Standard Features:
1.Smaller volume and higher power density;
2.Wide voltage design, it can work in the rated input voltage range of -15%~10%;
3.All the power below 90KW are equipped with built-in brake units, and have protection functions such as brake circuit, short circuit, over current, overload, and straight through of brake pipe;
4.Long life design, using high configuration of bus capacitance, to ensure longer life of drive;
5.Better EMC configuration scheme;
6.Fan drive circuit protection, when short circuit and locked-rotor in fan, it will not affect the power supply of other circuits.
Technical Specifications:
Items | Specifications | |
Basic functions | The highest frequency | 0~300Hz |
The carrier frequency | 0.5~8KHz, which can be automatically adjusted according to the load characteristics | |
Input frequency resolution | digital input: 0.01Hz analog input: highest frequency ×0.1% | |
Control mode | closed-loop vector FVC, V/F control | |
Starting torque | FVC 0Hz/180% | |
Speed adjustment range | 1:1000 FVC | |
Speed stabilization precision | ±0.02% FVC | |
Torque control precision | ±5% FVC | |
Overload capacity | 150%Ie 60s 180%Ie 3s | |
Inching control | Frequency is 0.00~50.00Hz, and the acceleration and deceleration time is 0.0~6500.0s | |
Simple PLC and multi-speed operation | Through the built-in PLC or DI terminal can achieve a maximum of 16-segment speed operation | |
The built-in PID process control | Easy to realize the process closed-loop control | |
Automatic voltage adjustment (AVR) | Can automatically keep the production voltage constant when the input voltage changes | |
Communication mode | Modbus-RTU和CAN_open | |
Protection function | Protection function | Short-circuit detection of power on motor, phase loss detection of input and output, overcurrent and overvoltage protection, undervoltage protection, overheat protection, overload protection, motor temperature protection, etc. |
JLS600 Series Servo Drive
Technical Specifications:
Items | Specifications |
Input voltage and frequency | Three phase AC(0.8~1.1)×220V frequency: 50/60Hz |
Speed ratio | 5000:1 |
Speed fluctuation ratio | <Rated speed×0.01% |
Speed frequency response | ≥300Hz |
Working mode | Inching, manual, internal speed, external speed and position |
Internal speed mode | Operates by closed-loop control of 3-segment internal speed selected by the input signal, and the speed value can be set |
External speed mode | Operates in closed-loop at the speed specified by the external analog voltage signal instruction |
External speed instruction mode | DC:-10v~+10v or 0~10v, through parameter selection |
The position mode | Operates by the closed-loop position control according to the given position command pulse. The direction and quantity of the position command pulse determine the running direction and angle of the servo motor, while the frequency of the position command pulse determines the running speed of the servo motor |
Position command pulse mode | Pulse/direction, CCW/CW pulse, A/B two-phase orthogonal pulse three modes; Maximum pulse frequency: 1MHz |
Position command electronic gear | Command pulse frequency doubling coefficient: 1~32767; Command pulse frequency division coefficient: 1~32767 |
Positioning accuracy | ±0.005°(17bit absolute encoder); ±0.018°(5000 line incremental encoder) |
Motor feedback input | Incremental encoder and absolute encoder of Tamagawa and Biss communication protocols |
Position feedback output | Motor feedback input direct output or motor feedback input frequency division output |
Communication bus | CAN_open Modbus-RTU |
Input signal | Servo enabling, alarm clearance, CCW disable, CW disable, CCW start, CW start, zero speed clamping, internal speed 1/2 selection 9 input points |
Output signal | Servo ready, servo alarm, position arrival/speed arrival, lock release, zero speed output, Z pulse (encoder zero) output 6 output points |
Protection function | include overvoltage, undervoltage, overcurrent, overload, overheating of the drive, overspeed, position out of tolerance, abnormal braking, abnormal encoder, motor overheating, etc. |
Operation and display | 5 keys, can be manual, inching, as well as parameter modification, setting, writing, backup and other operations; The 6-bit LED display can display information such as speed, current position, command pulse accumulation, position deviation, motor torque, motor current, rotor absolute position, input and output signal status, etc. |
Please download the PDF file to view the technical data, mounting, and outiline dimensions for different sizes.